DR-UPS40 - Fuentes Industriales
40A DC UPS Module
Main FeaturesŒŒ
- Battery controller for DIN Rail UPS system
- Parallel connection to DC BUS
- Suitable for 24V system up to 40A
- Installed on DIN Rail TS35 / 7.5 or 15
- Built-in battery test function
- Battery polarity protection
- Relay contact signal output and LED indicator for DC BUS OK, Battery Fail, and Battery Discharge
- Cooling by free air convection
- 3 years warranty
ŒŒ
ŒŒ
ŒŒ
ŒŒ
DC INPUT / DC BUS
- DC VOLTAGE (Typ.) Note.5 24 ~ 29V
- RATED CURRENT 40A
BATTERY INPUT / OUTPUT
- VOLTAGE RANGE (Typ.) 21 ~ 29V
- CURRENT RANGE 0 ~ 40A
- CHARGE CURRENT (Typ.) Note.4 2A
- EXTERNAL BATTERY (Typ.) 4 / 7 / 12AH / 24V
FUNCTION
- RELAY CONTACT RATING (max.) 30VDC, 1A
- DC BUS OK Relay contact : Short when DC voltage between 21~29V(¡Ó3%), relay contacts, LED(Green) : DC BUS OK : light ; DC BUS fail : dark
- BATTERY FAIL Note.2 LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark, Short when battery voltage falls below 21.9V(¡Ó3%) or battery failure is observed through the battery test function, relay contacts
- BATTERY DISCHARGE Relay contact : Short when battery in discharge condition, relay contacts, LED(Yellow) : Battery discharging : light ; Battery is not discharging or discharging current<2.0A : dark
ENVIRONMENT
- WORKING TEMP. -20 ~ +70¢J
- WORKING HUMIDITY -20 ~ +85¢J, 10 ~ 95% RH
- STORAGE TEMP., HUMIDITY -20 ~ +85¢J, 10 ~ 95% RH
- VIBRATION Component : 10 ~ 500Hz, 2G 10min./1cycle, 60min. each X, Y, Z axes ; Mounting : Compliance to IEC600068-2-6
SAFETY & EMC (Note 3)
- WITHSTAND VOLTAGE Terminal-Chassis :0.5KVAC, Relay Contacts-Terminal :0.5KVAC
- ISOLATION RESISTANCE Terminal-Chassis :>100M Ohms / 500VDC / 25¢J/ 70% RH
- EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
- EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A
OTHERS
- MTBF 161.9Khrs min. MIL-HDBK-217F (25¢J)
- DIMENSION 55.5*125.2*100mm (W*H*D)
- PACKING 0.55Kg; 20pcs/12Kg/1.29CUFT
- DC VOLTAGE (Typ.) Note.5 24 ~ 29V
- RATED CURRENT 40A
BATTERY INPUT / OUTPUT
- VOLTAGE RANGE (Typ.) 21 ~ 29V
- CURRENT RANGE 0 ~ 40A
- CHARGE CURRENT (Typ.) Note.4 2A
- EXTERNAL BATTERY (Typ.) 4 / 7 / 12AH / 24V
FUNCTION
- RELAY CONTACT RATING (max.) 30VDC, 1A
- DC BUS OK Relay contact : Short when DC voltage between 21~29V(¡Ó3%), relay contacts, LED(Green) : DC BUS OK : light ; DC BUS fail : dark
- BATTERY FAIL Note.2 LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark, Short when battery voltage falls below 21.9V(¡Ó3%) or battery failure is observed through the battery test function, relay contacts
- BATTERY DISCHARGE Relay contact : Short when battery in discharge condition, relay contacts, LED(Yellow) : Battery discharging : light ; Battery is not discharging or discharging current<2.0A : dark
ENVIRONMENT
- WORKING TEMP. -20 ~ +70¢J
- WORKING HUMIDITY -20 ~ +85¢J, 10 ~ 95% RH
- STORAGE TEMP., HUMIDITY -20 ~ +85¢J, 10 ~ 95% RH
- VIBRATION Component : 10 ~ 500Hz, 2G 10min./1cycle, 60min. each X, Y, Z axes ; Mounting : Compliance to IEC600068-2-6
SAFETY & EMC (Note 3)
- WITHSTAND VOLTAGE Terminal-Chassis :0.5KVAC, Relay Contacts-Terminal :0.5KVAC
- ISOLATION RESISTANCE Terminal-Chassis :>100M Ohms / 500VDC / 25¢J/ 70% RH
- EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
- EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A
OTHERS
- MTBF 161.9Khrs min. MIL-HDBK-217F (25¢J)
- DIMENSION 55.5*125.2*100mm (W*H*D)
- PACKING 0.55Kg; 20pcs/12Kg/1.29CUFT